A page from the OpenDepot.org service

Jump to the start of the main contents

Radzi, Z. and Yahya, N. A. and Abu Kasim, N.H. and Osman, N. A. Abu and Yusof, Z. Y. M. and Mohd, F. N. and Noor, N. H. M. and Jamaludin, M. and Othman, S. A. and Obaidellah, U. H. and Mohamed, N. H. and Kadir, R. and Nambiar, P. (2008) Validation of cone beam CT scan for measurement of palatal depth in study casts. 4th Kuala Lumpur International Conference on Biomedical Engineering 2008, Vols 1 and 2, 21 (1-2). pp. 758-761. ISSN 978-3-540-69138-9

[img]
Preview
PDF
Download (173Kb) | Preview

    Abstract

    The purpose of this study was to validate the use of digital dental study casts obtained from Cone beam CT Scan (CBCT) against gold standard; that is traditional dental study cast measured with digital caliper. Thirty-four study casts of Malaysian Aborigines were selected from Centre of Malaysian Pribumi Studies Databank. Palatal depth of each study casts were measured using Mitutoyo digital caliper. Subsequently, all the study models were scanned using i-CAT CBCT and the palatal depth were measured using i-CAT software. Data were analysed using SPSS version 12.0 where Intraclass correlation and paired T-test were employed. There was no significant difference in palatal depth between CBCT and Mitutoyo digital caliper (p>0.05). Average measures for Intraclass Correlation is 0.753 indicate that it is consistently good. Within the limitation of this study palatal depth measurement produced by CBCT was as accurate as the digital caliper. However, more samples and parameters should be added to further substantiate the result of this study.

    Item Type: Article
    Additional Information: Associate Prof. Dr. Noor Hayaty Binti Abu Kasim Department of Conservative Dentistry, Faculty of Dentistry Building, University of Malaya, 50603 Kuala Lumpur, MALAYSIA
    Uncontrolled Keywords: Validation; Dental Study Casts; Palatal Depth; Cbct & Digital Caliper; Plaster Models; Accuracy
    Subjects: Medicine and Dentistry
    Medicine and Dentistry > Clinical Dentistry
    Divisions: UNSPECIFIED
    Depositing User: Associate Prof. Dr. Noor Hayaty Abu Kasim
    Date Deposited: 09 Feb 2012 08:27
    Last Modified: 09 Feb 2012 08:27
    URI: http://opendepot.org/id/eprint/694